- Prepare end of aerial conductor for connection, i. e. insulate conductor of concentric cable, cutting off external insulation, plait and cable core at the same length (illus.1).
- Unscrew set screw in input socket (illus. 2).
- Put aerial conductor into it, so that socket point would go between plait and external insulation. The correctness of putting conductor of cable into input clamp should be checked (illus. 4).
- Screw home set screw in input socket (illus. 5).
- For output socket, the manner of action is analogous to that for input socket.
- Put socket into installation box, size Ø60 mm and depending on kind of socket, fix it with clamps or fixing tap screws.
- Put on frame with cover on socket body.